Factory Outlets Grewin Three Phase Current Transformer - DC Immunity Composite Cores (LLE-DC) – LLE
Factory Outlets Grewin Three Phase Current Transformer - DC Immunity Composite Cores (LLE-DC) – LLE Detail:
DC Current Immunity composite cores(LLE-DC)
Features:
- DC current immunity composite cores is combined with amorphous and nanocrystalline cores together
Magnetic features:
- Strong anti-DC-capacity
- Precision, the scope of application of 0.5-0.1 grade and applicable Current range 1.5-200A
- Good temperature stability
Allpications:
- DC current immunity transformers in electronic energy meter / watt-hour meter
- Metering transformer in electronic power system
Standard cores dimensions, Applicable CT accuracy , Maximal
- DC current immunity range
Part No. |
Core dimensions ODxIDxH |
Finished Dimensions ODxIDxH |
CT accuracy |
DC Compliance |
1 |
20×14×10 |
22.5×12.1×12.2 |
0.5-0.1 Class |
20-40A |
2 |
21×15×10 |
23.6×12.8×12.8 |
0.5-0.1 Class |
10-40A |
3 |
24×15.5×8 |
26.3×13.7×9.9 |
0.5-0.1 Class |
60A |
4 |
21×16×10 |
24.7×14.0×12.5 |
0.5-0.1 Class |
40-60A |
5 |
23×16×10 |
25.0×14.0×13.0 |
0.5-0.1 Class |
40-60A |
6 |
25×16×8 |
27.8×13.7×10.8 |
0.5-0.1 Class |
60A |
7 |
22×17×10 |
24.4×15.3×12.3 |
0.5-0.1 Class |
60A |
8 |
22×17×10A |
24.4×15.3×12.3 |
0.5-0.1 Class |
30A |
9 |
24×17×8 |
26.3×15.3×9.9 |
0.5-0.1 Class |
60A |
10 |
25×17×10 |
28.0×15.6×12.8 |
0.5-0.1 Class |
80A |
11 |
25×17×10A |
28.0×15.6×12.8 |
0.5-0.1 Class |
100A |
12 |
28×17×8 |
29.8×15.2×10.1 |
0.5-0.1 Class |
65A |
13 |
28×17×8A |
29.8×15.2×10.1 |
0.5-0.1 Class |
100A |
14 |
24×18×10 |
26.6×15.8×12.8 |
0.5-0.1 Class |
60-100A |
15 |
25×18×12 |
27.6×16.2×14.2 |
0.5-0.1 Class |
100A |
16 |
28×18×15 |
30.2×16.0×17.6 |
0.5-0.1 Class |
100A |
17 |
27×19×8 |
29.3×16.6×9.8 |
0.5-0.2 Class |
60-100A |
18 |
27×19×12 |
28.9×17.1×13.9 |
0.5-0.1 Class |
100-120A |
19 |
28×19×12 |
30.2×17.1×13.9 |
0.5-0.1 Class |
120A |
20 |
30×20×8A |
32.7×18.0×9.8 |
0.5-0.2 Class |
100-120A |
21 |
29×21×10 |
32.1×18.8×13.8 |
0.5-0.1 Class |
60-80A |
22 |
29×21×10A |
32.1×18.8×13.8 |
0.5-0.1 Class |
100A |
Notice:For your reference, the standard parameters above may vary according to your specifically designed turns and coil diameter of the transformer. We could design and manufacture the suitable cores according to your exact requirement.
Product detail pictures:
Related Product Guide:
ABB’s new transformer might help prevent long-term outages | High Denisty Iron-Based Amorphous Ribbon
Physicists demonstrate a simpler method of magnetic vortex excitation | Amorphous Toroid Core
Our commission should be to provide our end users and clients with very best excellent and aggressive portable digital products and solutions for Factory Outlets Grewin Three Phase Current Transformer - DC Immunity Composite Cores (LLE-DC) – LLE, The product will supply to all over the world, such as: Switzerland, Maldives, Iran, In order to meet more market demands and long-term development, a 150, 000-square-meter new factory is under construction, which will be put into use in 2014. Then, we shall own a large capacity of producing. Of course, we are going to continue improving the service system to meet the requirements of customers, bringing health, happiness and beauty to everyone.